Century Jefferson Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Krby Century Jefferson. Century Jefferson User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 40
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
2191
JDV28 cover
12/10/99 djt
INSTALLER / CONSUMER
SAFETY INFORMATION
30004177 2/08 Rev. 1
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency or the gas suppler.
WHAT TO DO IF
YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbors phone. Follow
the gas suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
This appliance may be installed in an
after market permanently located
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Jefferson
Direct Vent/Natural Vent
Gas Heater
Model: JDVBRN
Homeowners Installation
and Operating Manual
CE RTI FIE D
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - Gas Heater

2191JDV28 cover12/10/99 djtINSTALLER / CONSUMER SAFETY INFORMATION30004177 2/08 Rev. 1PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIAN

Strany 2 - Table of Contents

1010Jefferson Direct Vent/Natural Vent Gas Heater 30004177Vent Termination ClearancesYour stove is approved to be vented either through the side wall,

Strany 3 - 30004177

11Jefferson Direct Vent /Natural Vent Gas Heater30004177VVVVVVVXXXDEBBBCBMBAJKFLVENT TERMINATION AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTED

Strany 4

1212Jefferson Direct Vent/Natural Vent Gas Heater 30004177Fig. 10 Termination clearances.Outside CornerInside CornerTermination ClearancesTermination

Strany 5 - Attention

13Jefferson Direct Vent /Natural Vent Gas Heater30004177Venting Requirements and Options - Direct Vent ONLYApproved Vent System ComponentsThe Jefferso

Strany 6 - Installation Requirements

1414Jefferson Direct Vent/Natural Vent Gas Heater 30004177Assembly Procedures Failure to position the parts in accor-dance with these diagrams or fail

Strany 7 - 12/3/99 djt

15Jefferson Direct Vent /Natural Vent Gas Heater30004177Venting System Assembly - Direct VentGeneral InformationThe Jefferson is approved for installa

Strany 8 - Vertical Run (in feet)

1616Jefferson Direct Vent/Natural Vent Gas Heater 300041774. Attach the Inner Vent Assembly to the stove.• Run a bead of sealant around the bottom e

Strany 9 - Direct Vent Only

17Jefferson Direct Vent /Natural Vent Gas Heater300041772. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”)

Strany 10

1818Jefferson Direct Vent/Natural Vent Gas Heater 300041776. Install the elbow using 3 sheet metal screws at each joint. 7. Measure, and cut if need

Strany 11 - meet these requirements

19Jefferson Direct Vent /Natural Vent Gas Heater30004177ST218install snorkel12/6/99 djtWall Screws and AnchorsSnorkel Termination CapWaterproof Se

Strany 12 - Venting Runs

22Jefferson Direct Vent/Natural Vent Gas Heater 30004177PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and

Strany 13 - Direct Vent ONLY

2020Jefferson Direct Vent/Natural Vent Gas Heater 30004177ST221vent thru roof12/99Storm CollarSealantUpper edge of flange goes under upper shinglesFl

Strany 14 - Assembly Procedures

21Jefferson Direct Vent /Natural Vent Gas Heater30004177Install the Log Set1. Remove the logs from their packaging and inspect each piece for damage.

Strany 15 - 12/13/99 djt

2222Jefferson Direct Vent/Natural Vent Gas Heater 30004177Connect the Gas Supply LineCheck the Rating Plate attached by a steel cable to the firebox, t

Strany 16 - 12/4/99 djt

23Jefferson Direct Vent /Natural Vent Gas Heater300041773. Pull the top edge of the glass and frame assembly away from the firebox and lift it off its

Strany 17 - 2/99 djt

2424Jefferson Direct Vent/Natural Vent Gas Heater 30004177Fig. 41 Remove and replace injector orifices.ST353ainjector orificereplace3/21/00 djt9

Strany 18 - Vent Termination Below Grade

25Jefferson Direct Vent /Natural Vent Gas Heater30004177OperationYour First FireRead these instructions carefully and familiarize yourself with the bu

Strany 19 - General Information

2626Jefferson Direct Vent/Natural Vent Gas Heater 300041773. Open control access panel.4. Push in gas control knob slightly and turn clock-wise t

Strany 20 - Install the Vent Pipe

27Jefferson Direct Vent /Natural Vent Gas Heater30004177Troubleshooting / Honeywell #8420 Gas Control SystemNOTE: Before troubleshooting the gas contr

Strany 21 - Install the Log Set

2828Jefferson Direct Vent/Natural Vent Gas Heater 30004177Conversion PrecautionsBefore proceeding, turn control knob on valve to OFF and turn gas supp

Strany 22

29Jefferson Direct Vent /Natural Vent Gas Heater30004177• Remove pilot orifice with needlenose pliers. (Fig. 57) NOTE: Use a wrench to hold pilot tube

Strany 23 - 3/20/00 djt

3Jefferson Direct Vent /Natural Vent Gas Heater30004177The Jefferson Direct Vent/Natural Vent Room Heater, Model No. JDVBRN, is a vented gas applianc

Strany 24 - 1/31/00 djt

3030Jefferson Direct Vent/Natural Vent Gas Heater 30004177MaintenanceYour Jefferson Gas Heater will provide years of service with minimal upkeep. The

Strany 25 - Operation

31Jefferson Direct Vent /Natural Vent Gas Heater30004177Gasket ReplacementThe Jefferson Gas Heater uses a ‘tadpole’ type gasket to seal between the gl

Strany 26 - To Turn Off Gas To Heater

3232Jefferson Direct Vent/Natural Vent Gas Heater 30004177NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MU

Strany 27 - CORRECTIVE ACTION

33Jefferson Direct Vent /Natural Vent Gas Heater300041771a1b1c1d1eCEMENT4521091137171829301283132151633342122 23242527263619353671420a,b

Strany 28 - Fuel Conversion Instructions

3434Jefferson Direct Vent/Natural Vent Gas Heater 30004177 Ref. Descripción JDVB 7. Right End 30000681 8. Front 30000683 9. Glass 200021

Strany 29 - 1/28/00 djt

35Jefferson Direct Vent /Natural Vent Gas Heater30004177Optional AccessoriesFan KitsFK28 FanThe FK28 fan helps distribute heated air from within the fi

Strany 30 - Maintenance

3636Jefferson Direct Vent/Natural Vent Gas Heater 30004177

Strany 31 - 12/10/99

37Jefferson Direct Vent /Natural Vent Gas Heater30004177

Strany 32 - 1/11/00 djt

3838Jefferson Direct Vent/Natural Vent Gas Heater 30004177

Strany 33 - Model: JDVBRN

39Jefferson Direct Vent /Natural Vent Gas Heater30004177This Warranty gives you specific legal rights and you may also have other rights that vary in e

Strany 34

44Jefferson Direct Vent/Natural Vent Gas Heater 30004177Requirements for the Commonwealth of MassachusettsAll gas fitting and installation of this heat

Strany 35 - Optional Accessories

Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) JDVBRN 60.7 JDVBRP 60.72695 Meadowvale Blvd. • Mississauga, Ontario, Canada

Strany 36

5Jefferson Direct Vent /Natural Vent Gas Heater30004177ST205FDV28dimensions12/3/99 djt28"(724 mm)24"(610 mm)3"(76 mm)14"(3

Strany 37

66Jefferson Direct Vent/Natural Vent Gas Heater 30004177Installation RequirementsThe installation must conform with local codes or, in the absence of

Strany 38

7Jefferson Direct Vent /Natural Vent Gas Heater30004177Hearth Requirements The Jefferson Heater must be installed on rigid flooring. When the heater is

Strany 39 - TWO YEAR LIMITED WARRANTY

88Jefferson Direct Vent/Natural Vent Gas Heater 30004177Gas Specifications Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/

Strany 40 - CFM Corporation

9Jefferson Direct Vent /Natural Vent Gas Heater30004177Vent Termination ClearancesWhen planning the installation, consider the location of the vent te